SELECTION
Details required for couplings selection
1. Type of driven machine and operating hours per day.
Speed and power absorbed by driven machine (if absorbed power is not
known, calculate on power rating of
prime mover).
3. Diameter of shafts to be connected.
4. Distance between two shaft ends in case of spacer coupling.
PROCEDURE
a) Service Factor
Determine the required service factor from table.
b) Design Power
Multiply the normal running power by the service factor. This gives the
Design Power which is used as a basis for selecting the coupling.
c) Coupling size
Depending upon the type of coupling required, refer to respective power
rating table. Power rating can be interpolated in relation to speed
parameters.
d) Bore Size
Check from the dimension table to see if bore capacity of the coupling
is adequate. Otherwise select next higher size coupling.
| Type of Driven Machine | Type of Driving Unit | ||
| Electric Motors & Steam Turbines | Internal Combustion Engines | ||
| More than six cylinders | Less than six cylinders | ||
|
Uniform Load Agitators, Brewing machinery, Centrifugal compressors and pumps, Belt conveyors, Dynamometers, Lineshafts, Fans upto 7.5 kW, Blowers and exhausters except positive displacement, Generators. |
1.0 |
1.5 |
2.0 |
|
Moderate Shock Clay working machinery, General machine tools, Paper mill beaters and winders, Rotary pumps, Rubber extruders, Rotary screens, Textile machinery, Marine propellers and fans over 7.5 kW. |
1.5 |
2.0 |
2.5 |
|
Heavy Shock Bucket elevators, Cooling tower fans, Piston compressors and pumps, foundry machinery, metal presses, Paper mill calendars, Hammer mills, Presses and pulp grinders, Rubber calendars, Pulverisers and positive displacement blowers. |
2.0 |
2.5 |
3.0 |