SELECTION

Details required for couplings selection
 
1. Type of driven machine and operating hours per day.
    Speed and power absorbed by driven machine (if absorbed power is not known, calculate on power rating of
    prime mover).
3. Diameter of shafts to be connected.
4. Distance between two shaft ends in case of spacer coupling.
  
PROCEDURE
 
a) Service Factor
Determine the required service factor from table.
 
b) Design Power
Multiply the normal running power by the service factor. This gives the Design Power which is used as a basis for selecting the coupling.
 
c) Coupling size
Depending upon the type of coupling required, refer to respective power rating table. Power rating can be interpolated in relation to speed parameters.
 
d) Bore Size
Check from the dimension table to see if bore capacity of the coupling is adequate. Otherwise select next higher size coupling.

Type of Driven Machine Type of Driving Unit
Electric Motors & Steam Turbines Internal Combustion Engines
More than six cylinders Less than six cylinders
Uniform Load
Agitators, Brewing machinery, Centrifugal compressors and pumps, Belt conveyors, Dynamometers, Lineshafts, Fans upto 7.5 kW, Blowers and exhausters except positive displacement, Generators.
1.0
 
1.5
 
2.0
 
Moderate Shock
Clay working machinery, General machine tools, Paper mill beaters and winders, Rotary pumps, Rubber extruders, Rotary screens, Textile machinery, Marine propellers and fans over 7.5 kW.
1.5
 
2.0
 
2.5
 
Heavy Shock
Bucket elevators, Cooling tower fans, Piston compressors and pumps, foundry machinery, metal presses, Paper mill calendars, Hammer mills, Presses and pulp grinders, Rubber calendars, Pulverisers and positive displacement blowers.
2.0
 
2.5
 
3.0